AirQualityMeasurementThequalityofgasorcompressedairwithinasystemdependstoalargeextentonthecontinuousmonitoringoftheresidualoilcontentandthenumberofparticles.Oursystemsfordeterminingtheresidualoilcontentandmeasuringtheparticlesincompressedairandgasareavailablebothinastationaryandinamobileversion.Inthisway,weoffertherightsystemforeveryapplicationtomeettherequirementsofISO8573aseasilyaspossible.OilCheck400ResidualOilMeasurement0.01 –2mg/m3PC400ParticleCounterParticleCounter0.1 –5umDPM400DewPoint...
OilCheck400OilCheck400ContinuousOilVaporMeasurementinCDACompressedaircontaminatedwithoilisadangerforproductionsystems,theenvironmentandalsohealth.Sinceoilcontaminationcanoccuratanypointincompressedairprocessing,theriskshouldnotbeunderestimated,especiallyinsensitiveproductionareasoftheelectronics,chemical,pharmaceutical,foodandbeverageindustries.TheOILCHECK400monitoringsystemcontinuouslycontrolsthecompressedairaccuratelyandaccordingtoapplicablestandardsfortheresidualoilvapourconcentrationandsupportsyouforretaining...
ParticleCounterPC400ParticleCounterPC400Station &PortableSolutionaccordingtoISO8573ThehighlypreciseopticalparticlecounterPC400measuresparticlesfromasizeof0.1 µmandisthereforesuitableformonitoringofthecompressedairqualityclass1 (ISO8573).Thecorrectfunctionthefiltrationelementsmountedinthecompressedairismonitoredandpossiblefilterperforationsarerecognizedimmediately.Thecompressedairflowthroughtheparticlecounterisautomaticallysupervised.KeyFeaturesDataloggerforlong-termmonitoringDisplayshowstrendcurves (onlineand...
DewPointMetersToday,modernproductionprocesscannotbeimaginedwithoutcompressedairasaversatileandreliableenergysource.Ifcompressedairisnotdriedbeforefeedingintothepipelinenetworkortheairdryerismalfunctioning,thenitresultsintosubstantialamountofcondensateformation.Manyprocessesaredamagedwhenexposedtotoomuchmoisture,leadingtostoppagesforun-scheduledmaintenance,lossofproductandresultinproductiondowntime.Theexactmonitoringofdewpointtemperatureincompressedairsystems,dryersforplasticandotherindustrialmanufacturingprocesses...
FA500FA500DewPointMeterwithintegrateddisplay &alarmrelayTheFA500dewpointmeterareidealformeasurementoftracemoisture;forexample,incompressedairsystemsorinrefrigerationordesiccantdryers.Dewpointmeasuringinstrumentsareusedinthepharmaceuticalandrawmaterialindustries,inbuildingservicesengineering (HVAC),forcleanroomsaswellasinproductionandprocesstechnologiesandininjectionmoulding.Inotherwords,wherevermeasurementandmonitoringofdewpointortracemoistureplaysanimportantrole.KeyFeaturesOperatingpressurerange -1…50bar...
FA550FA550DewPointMeterwithintegratedIP67aluminiumdie-casthousingTheFA550isideallysuitedforoutdoordewpointmeasurementandreliablydeterminesdewpointsevenunderharshindustrialconditions.KeyFeaturesRobust,waterproofdie-castaluminumhousing,IP67Alarmrelay -limitvalueadjustableviabuttons (max60VDC,0.5A)4 ...20mAanalogoutputOptional:2pieces4 ...20mAanalogoutpute.g.fordewpointandtemperatureExtremelylong-termstableFastadjustmenttimePressureresistantupto500bar (optional)NEW:ModbusRTUinterfaceNEW:Ethernetinterface (optional)...
DP500 /DP510DP500 /DP510PortableDewPointMeterwithintegrateddataloggerThedewpointmeterDP500withdataloggeristheidealportableserviceinstrumentfordewpointmeasurementforalltypesofdryersdownto -80°Ctddewpoint.The3.5“graphicdisplaywithtouchscreenmakestheoperationveryeasy.Thegraphicindicationofcolouredmeasuringcurvesisunique.Idealformeasurementofthecurrentdewpointandforgraphicindicationofthedewpointcurve/theswitchingbehaviourofthedryeroveralongerperiodoftime.Upto100millionmeasuredvaluescanbestored
DP400DP400PortableDewPointMeterwithintegrateddataloggerTheportabledewpointmeterwithintegrated,rechargeablebatteryhasbeendevelopedespeciallyfortheenduse.Besidesahighlyprecisedewpointsensorthedevicealsocontainsaprecisepressuresensorupto16bar.Soinadditiontothedewpointin °Ctd,thetemperaturein °Candthelinepressureinbaralsofurthermoistureparameters (%RH,mg/m3,g/m3)aswellaspressuredependentmeasuringvalues (g/kg,ppmv/v,atm.dewpoint °C)canbecalculated.KeyFeaturesPrecisedewpointmeasurementdownto -80°CtdRobust...
FA510 /FA515FA510 /FA515DewPointSensor -80to +20oCtd & -20to +50oCtdThenewgenerationofCSInstrumentsdewpointsensorsFA510 /515comewith2and3wirestechnology,itcanbeproviding4…20mAandRS485 (Modbus-RTU)bothoutputsignalatthesametimeandenablesareliableandlong-termstablemonitoringofthedewpointinindustrialapplication.WithadigitalRS485interface,allvalueslikee.g.dewpoint,temperature,absolutehumidity...whicharemeasuredandcalculatedbythedewpointsensorcanberetrievedviatheModbusprotocol.Thesensorincludedsinter
FA510 /FA515FA510 /FA515DewPointSensorwithATEXapprovalforexplosiveareasThenewFA515Exdewpointsensorsprovidereliable,longtermstabledewpointmeasurementinindustrial,potentiallyexplosiveatmospheresorhazardousarea.Thesensorcomesreadytouseandsimpletoinstallwithyourchoiceof4-20mAoutputsandcanbeusedinmanynon-aggressivegases.KeyFeaturesRobustdesignPressureresistantupto500barLong-termstablehumiditysensor,approvedforyears4...20mAanalogueoutputin2-wiresystemFurtherparametersadjustableviasoftware: %RH,g/m³,mg/m³,...